Types of Tests
AMCA International's lab performs tests on the following products:
Fans
Air performance testing includes:
- Development of fan curves.
- Measurement of airflow, pressure, power, and efficiency.
Test standards that apply to air performance testing include:
- AMCA International's 210, Laboratory Methods of Testing Fans for Aerodynamic Performance Rating
- AMCA International's 220, Test Methods for Air Curtain Units
- AMCA International's 230, Laboratory Methods of Testing Air Circulator Fans for Rating
- AMCA International's 240, Laboratory Method of Testing Positive Pressure Ventilators for Rating
- ISO 5801, Industrial Fans - Performance Testing Using Standardized Airways
- ENERGY STAR Program Requirements for Residential Ventilating Fans
Sound testing includes:
- Inlet sound power.
- Outlet sound power.
- Total sound power.
Test standards that apply to sound testing include:
- AMCA International's 300, Reverberant Room Method for Sound Testing of Fans
- ENERGY STAR Program Requirements for Residential Ventilating Fans
Dampers
- Pressure drop.
- Leakage performance.
Test standards that apply to damper testing include:
- AMCA International's 500-D, Laboratory Methods of Testing Dampers for Rating
Louvers
- Pressure drop.
- Leakage.
- Resistance to water and wind driven rain.
- Transmission loss of acoustic louvers.
- Sound testing is from ASTM Standard E477-99.
Test standards that apply to louver testing include:
- AMCA International's 500-L, Laboratory Methods of Testing Air Louvers for Rating
Airflow Measurement Stations
- Accuracy and pressure drop.
Test standards that apply to airflow measurement station testing include:
- AMCA International's 610, Methods of Testing Airflow Measurement Stations for Rating
Test standards that apply to fire, smoke, combination fire/smoke dampers testing include:
- AMCA International's 500-D, Laboratory Methods of Testing Dampers for Rating
- Underwriters Laboratories 555, Fire Dampers
- Underwriters Laboratories 555S, Smoke Dampers
Contract Testing
Non-standard tests can be performed to meet customer requirements when within the physical capabilities of AMCA International's facilities.
Facilities:
- Reverberant Sound Rooms (Four)
Range in size from 6,300 cu. ft. to 61,700 cu. ft.
- Water Penetration Test Facilities (Two)
Chambers are capable of simulating three or eight inches per hour of rainfall and wind speeds of 29 or 50 mph.
- Multi Nozzle Chambers (Two Inlet, Two Outlet)
Capable of measuring airflow up to 88,000 cfm.
- Circulator Fan
Tests circulator fans up to diameters of 96 in.