Laboratory testing facility capabilities of the AMCA Partner Lab—KTC - Korea Testing Certification

AMCA 210Small Chamber
(MPIR1240)
Large Chamber
(MPIR1260)
Large Chamber
(MPIR1560)
Figure 12 Max Outlet Area - Perpendicular Rotation 1.368 m2 (14.72 ft2) 4 m2 (43.04 ft2) NA

Figure 12 Max Outlet Area - Parallel Rotation
(Vane Axial Fans Only)

0.77 m2 (8.29 ft2)

2.25 m2 (24.21 ft2)

NA
Figure 12 Max Outlet Area - Parallel Rotation 0.493 m2 (5.31 ft2) 1.44 m2 (15.49 ft2) NA
Figure 15 Max Inlet Area - Any Rotation NA 7.2 m2 (77.47 ft2)
Max Airflow at 0 in. wg 24.3 m3/s (51,383 cfm) 71.81 m3/s (151,855 cfm)
Max Static Pressure 2936.5 Pa (11.8 in wg) 6852.9 Pa (27.6 in wg)
Max Brake Horsepower

22 kW @ 3540
149 kW @ 1750

Max Dynamometer Speed 3540 RPM (22kW)
1750 RPM (All Others)

 

AMCA 300 
Max volume of Test Unit with Duct Work 38.08 m3 (1344.8 ft3)
Frequency  63  125  250  500  1000  2000  4000  8000  LwA 
Approx Min Fan Lw
Reverb Room (dB)
 77 59 50 44 36 32 38 46 54